CFS polypropylene loops are ideal for applications where the corrosion of a mild steel loop could be critical.
Geometry
Expand
Profile
tn
Load group
D [mm]
Metric thread
L [mm]
Length
Hef [mm]
Min. effective embedment depth
POLY-150
0.15
6
200
135
POLY-250
0.25
8
220
150
POLY-360
0.36
10
235
155
POLY-500
0.5
12
255
175
POLY-875
0.875
14
280
190
POLY-1000
1
16
330
225
POLY-1200
1.2
15
330
225
Load Data
SKU
Max. load capacity [kN]
Axial and Angled Loads
POLY-150
1.5
POLY-250
2.5
POLY-360
3.6
POLY-500
5
POLY-875
8.75
POLY-1000
10
POLY-1200
12
Minimum Concrete Cover for Aluminium Ferrules:
Aluminium reacts with fresh alkaline concrete and with chlorides. If the ferrule is cast close to a concrete surface, the expansive corrosion products can crack and spall the cover. The ferrule must therefore be positioned away from all faces and edges of the element.
The minimum concrete cover to the ferrule, c_Ferrule, measured to the outer face of the ferrule on all sides, shall satisfy:
c_Ferrule ≥ 2 × c_min,dur
where c_min,dur is the minimum cover for durability for the element’s exposure class, determined in accordance with BS EN 1992-1-1 §4.4.1.2 and BS 8500-1.
The element must be thick enough to provide this cover on both faces: minimum element thickness ≥ ferrule diameter + 2 × c_Ferrule. Loops must be installed to the minimum effective embedment depth Hef given in the geometry table. CFS Polypropylene Loops with aluminium ferrules are not suitable for use in thin elements such as paving units or cladding, in elements that will be permanently or intermittently wet in service, or in concrete exposed to chlorides (exposure classes XD and XS, including de-icing salts and marine environments). For these applications contact CFS for an alternative lifting solution.