ETA approved stainless steel anchor with high corrosion resistance, ideal for axial/transverse loads with a range of embedment depths.
Features
ETA Approved
European Technical Assessment ETA-16/0918 , valid for cracked and non-cracked normal-weight concrete.
High Capacity
Extensively tested with robust construction for high load capacity and reliable performance.
Design Software
Easy design the stud anchor in any application through the FixPro software.
Geometry
Click to interact
Expand
SKU
D [mm]
Metric thread
D1 [mm]
Diameter
L [mm]
Length
Lth [mm]
Screw in depth
LH [mm]
Socket Length
Hef [mm]
Min. effective embedment depth
SL-P-A4-M12-104
12
15.5
104
25
42
97
SL-P-A4-M16-83
16
21.1
83
27
56
75
SL-P-A4-M16-108
16
21.1
108
27
56
100
SL-P-A4-M16-183
16
21.1
183
27
56
175
SL-P-A4-M20-140
20
27
140
32
70
132
SL-P-A4-M20-165
20
27
165
32
70
157
SL-P-A4-M20-190
20
27
190
32
70
182
SL-P-A4-M20-240
20
27
240
32
70
232
SL-P-A4-M24-173
24
31
173
38
87
165
SL-P-A4-M24-248
24
31
248
38
87
240
SL-P-A4-M24-298
24
31
298
38
87
290
SL-P-A4-M30-213
30
39.5
213
56
97
201
SL-P-A4-M30-238
30
39.5
238
56
97
226
Load Data
Click to interact
Expand
SKU
Hmin
Min. Element Thickness
cmin [mm]
Min. edge distance
Smin [mm]
Min. anchor spacing
VRd [kN]
Shear load C20/25
NRd [kN]
Tensile load C20/25
SL-P-A4-M12-104
L + Cnom
50
50
8.6
14.3
SL-P-A4-M16-83
L + Cnom
50
50
16.4
18.4
SL-P-A4-M16-108
L + Cnom
50
50
16.4
27.4
SL-P-A4-M16-183
L + Cnom
50
50
16.4
27.4
SL-P-A4-M20-140
L + Cnom
50
50
28.3
42.9
SL-P-A4-M20-165
L + Cnom
50
70
28.3
47.2
SL-P-A4-M20-190
L + Cnom
50
50
28.3
47.2
SL-P-A4-M20-240
L + Cnom
50
50
28.3
47.2
SL-P-A4-M24-173
L + Cnom
50
50
33.8
56.4
SL-P-A4-M24-248
L + Cnom
50
50
33.8
56.4
SL-P-A4-M24-298
L + Cnom
50
50
33.8
56.4
SL-P-A4-M30-213
L + Cnom
100
100
57.1
76.7
SL-P-A4-M30-238
L + Cnom
100
100
57.1
76.7
Hmin is calculated by: Socket length (L) + Concrete cover (Cnom) [Cnom acc. to EN 1992-1 with Cnom ≥ 20 mm]
Intermediate values can be obtained by linear interpolation. Compressive forces on the anchors are not permitted.
The above capacities assume no close edge distance, please refer to FixPro software for actual capacities given your installation parameters.
Custom versions with length up to 525mm available. European Technical Assessment ETA-16/0918 CE Marked.