a drawing of a metal pole with holes in it
1 of 2

WIN2 Windpost

WIN2


L-section Windposts are ideal for high wind load areas and narrow cavities where C-section Windposts are unsuitable. Their superior design provides excellent lateral restraint, enhancing building stability and longevity.
NBS Source

Features

Arrow Square Up

Vertical Tolerance

Achieve remarkable 20mm up/down tolerance using any of our Windpost design profiles.
Align Bottom

Enables Design Flexibility

Ensures structural safety while permitting the design of higher walls in high wind zones.
Arrow Fat Line Right

Discrete Integration

CFS Windposts ensure seamless support by integrating subtly within wall structures.

Geometry

SKU

X [mm]

Depth

y [mm]

Width

t [mm]

Thickness
WIN2-125-70-4
125
70
4
WIN2-130-70-6
130
70
6
WIN2-140-70-4
140
70
4
WIN2-150-70-4
150
70
4
WIN2-150-70-6
150
70
6
WIN2-150-80-8
150
80
8
WIN2-160-70-5
160
70
5
WIN2-170-70-4
170
70
4
WIN2-170-70-5
170
70
5
WIN2-170-80-8
170
80
8
WIN2-180-80-8
180
80
8
WIN2-185-70-6
185
70
6
Specification: WIN2-125-70-4-3500 L-type Windpost, 125 depth, 70 width, 4 mm thickness, 3.5m height supplied with slots for brick ties at 225mm centres

Recommended Resistance Per Post

SKU

2.5m

3.0m

3.5m

4.0m

4.5m

5.0m

5.5m

6.0m

WIN2-125-70-4
6.25
5.22
4.06
3.20
2.57
2.10
1.76
1.50
WIN2-130-70-6
9.75
8.25
6.55
5.20
4.19
3.45
2.86
2.40
WIN2-140-70-4
7.73
6.45
5.32
4.28
3.47
2.85
2.37
1.98
WIN2-150-70-4
8.78
7.32
6.27
5.04
4.14
3.40
2.86
2.40
WIN2-150-70-6
6.25
10.80
9.28
7.44
6.08
5.00
4.18
3.54
WIN2-150-80-8
16.28*
14.58
12.50
10.12
8.28
6.85
5.72
4.86
WIN2-160-70-5
12.30
10.26
8.79
7.32
5.99
5.00
4.18
3.54
WIN2-170-70-4
11.08
9.24
7.91
6.84
5.63
4.70
3.96
3.36
WIN2-170-70-5
13.78
11.46
9.84
8.84
6.98
5.80
4.90
4.14
WIN2-170-80-8
16.28*
18.45
15.82
13.72
11.30
9.45
7.98
6.78
WIN2-180-70-5
15.30
12.75
10.92
9.56
8.01
6.70
5.67
4.80
WIN2-180-80-8
16.28*
19.53*
17.61
15.40
13.01
10.90
9.19
7.89
WIN2-185-70-6
16.28*
16.02
13.72
12.00
10.17
8.55
7.21
6.18
*Indicate resistance limited by tie capacity. Windposts are designed as ‘simply supported beams’ with a maximum deflection of span/360. The tables above include examples with maximum design loads to BS EN 1993 (Eurocode 3). The design resistances shown should be compared to factored loads. The thickness of L-section Windposts varies depending on the load they are required to support and the height of the opening they are installed in. The length of L-section Windposts can vary depending on the height of the opening they are supporting. CFS Windposts are designed to B EN1993 – Eurocode 3 and manufactured to BS EN1090-2, UKCA and CE marked

Materials

Component

Material

Description

Post
Stainless steel
Carbon steel and stainless steel

Resources

WIN2 Technical Datasheet

PDF
0.25mb

Windpost Category Brochure

PDF
5.04mb

Related products