Geometry

360
Click to interact
a drawing of a screw on a black background .
1 of 2

SKU

tn

Load group

D [mm]

Diameter

Lth [mm]

Screw in depth

L [mm]

Length
CRA-16-80
1.2
16
32
80
CRA-20-100
2
20
40
100
CRA-24-115
2.5
24
48
115
CRA-30-120
4
30
60
120
CRA-30-150
4
30
60
150

Load Data

360
Click to interact
a drawing of a box with a screw in it
a drawing of a metal object with the letters f and q on it
1 of 2

SKU

Max. Load Capacity (C15)

Max. Load Capacity (C25)

Installation Parameters

With rebar

Without rebar

With rebar

Without rebar

Hmin [mm]

Min. element thickness

Cmin [mm]

Min. edge distance

Fᵥ [kN]

Axial load

Fq [kN]

Shear load 45° to 90°

Fᵥ [kN]

Axial load

Fᵥ [kN]

Axial load

Fq [kN]

Shear load 45° to 90°

Fᵥ [kN]

Axial load
CRA-16-80
110
110
-
13.1
8.2
-
14.4
11.9
CRA-20-100
130
140
14.1
14.4
12.9
22.5
14.4
16.7
CRA-24-115
150
160
18.8
17.2
16.2
31.3
20.7
20.9
CRA-30-120
150
170
28.4
19
17.3
40.8
20.7
22.3
CRA-30-150
180
210
33.4
28.7
24.3
50.2
36.9
31.4
The table above shows the application of these sockets as lifting points. These tables show a typical situation and you should check your situation is within these parameters. If your situation falls out of these parameters, please contact CFS for bespoke advice and calculations. Where two or more sockets are in use, they should be spaced ataminimumof2xCmin apart. Some Axial Loads require reinforcement as shown below. Please ensure that the reinforcement touches the end plate of the socket. Easy to install with no anchorage reinforcement