The cranked rebar lifting point allows the Sandwich Panel Anchor to be placed near the centre of gravity. Ideal for lifting sandwich elements with a compensating beam during install.
Features
Offset Lifting
Cranked lifter allows safe lifting of sandwich panels with an off-centre centre of gravity.
Long Anchorage
High capacity due to increased anchorage in concrete.
Extensive Test Data
Testing has been conducted on the lifter for a range of edge distances and configurations to validate the design with confidnece ence.in design.
Geometry
Click to interact
Expand
1 of 2
SKU
Rd [mm]
Diameter
O [mm]
Offset
L [mm]
Length
Lth [mm]
Screw in depth
SPA-24-70
24
70
400
43
SPA-30-70
30
70
490
56
SPA-36-70
36
70
610
69
Load Data
Click to interact
Expand
1 of 2
SKU
Installation Parameters
Axial (Fv)
Angled (Fs) <30˚
Hmin [mm]
Min. element thickness
Cmin [mm]
Min. edge distance
2x SPA
Fv
4x SPA
Fv
2x SPA
Fs
4x SPA
Fs
SPA-24-70
170
150
19.2
38.5
16.6
33.2
170
200
25.6
51.3
22.1
44.2
170
250
32.1
64.1
27.6
55.3
170
300
38.5
76.9
33.2
66.3
170
350
38.5
76.9
33.2
66.3
SPA-30-70
170
150
26.4
52.8
22.7
45.5
170
200
35.2
70.3
30.3
60.6
170
250
44
87.9
37.9
75.8
170
300
52.8
105.5
45.5
90.9
170
350
61.5
123.1
53.1
106.1
SPA-36-70
170
150
40.4
80.8
34.8
69.6
170
200
53.9
107.7
46.4
92.8
170
250
67.3
134.6
58
116.1
170
300
80.8
161.5
69.6
139.3
170
350
94.2
188.5
81.2
162.5
170
400
107.7
215.4
92.8
185.7
Max elements weights for lifting assuming 1.3 dynamic load factor and 1.16 angled load factor. Minimum spacing=2x minimum edge distance. For panels 110 external leaf /75 insulation /170 structural leaf thickness.
Materials
Component
Material
Description
Socket
Carbon steel
Threaded sleeve made of precision tube according to EN 10305
Rod
Carbon steel
Tie rod according to DIN 488
Coating
Zinc
Bright Zinc Plated galvanised steel with a layer thickness of 4 to 6 μm