Stainless steel waved anchor short with reduced height, ideal for long precast elements like bridge beams.
Geometry
Click to interact
Expand
1 of 3
SKU
Rd [mm]
Diameter
L [mm]
Length
Lth [mm]
Screw in depth
Ds [mm]
Socket rebar dim
t [tn]
Load group
WASS-12-108
12
108
22
8
0.5
WASS-16-167
16
167
27
12
1.2
WASS-20-187
20
187
35
16
2
WASS-24-240
24
240
43
20
2.5
WASS-30-300
30
300
56
20
4
WASS-36-380
36
380
69
25
4
WASS-42-450
42
450
80
28
8
Load Data
Click to interact
Expand
1 of 3
SKU
Installation Parameters
Max. Load Capacity (C15)
Max. Load Capacity (C25)
Hmin [mm]
Min. element thickness
cmin [mm]
Min. edge distance
Fᵥ [kN]
Axial load up to 10°
Fₛ [kN]
Angled load 10° to 45°
Fq [kN]
Shear load 45° to 90°
Fᵥ [kN]
Axial load up to 10°
Fₛ [kN]
Angled load 10° to 45°
Fq [kN]
Shear load 45° to 90°
WASS-12-108
140
95
5
5
4.3
7
7
5.6
WASS-16-167
195
135
14.4
12
13.4
18.5
15.5
14
WASS-20-187
100
250
14.6
14.6
9
18.9
18.8
11.5
125
250
18.2
18.2
11.9
23.1
23.1
14.5
150
250
21.6
21.6
13.5
24.8
24.8
17.4
175
250
24.8
24.8
15.8
24.8
24.8
20.3
WASS-24-240
100
300
18.4
16.7
9
23.7
21.5
11.6
150
300
26.5
22.6
13.5
30.5
29.3
17.4
175
300
28.5
26.6
15.8
30.5
30.5
20.3
200
300
30.5
30.5
18
30.7
30.5
23.2
WASS-30-300
125
350
23.8
23.8
17.8
30.7
30.7
23
150
350
28.5
28.5
21.4
36.8
36.8
27.6
175
350
33
33
25
42.9
43.3
32.2
200
350
37.4
37.4
28.5
46.1
46
36.8
250
350
46.1
46.1
35.7
46.1
46.1
46.1
WASS-36-380
150
500
39.9
39.4
20.2
51.6
50.8
26
175
500
46.6
45.9
24.6
60.2
59.3
31.8
200
500
57.4
52.5
28.6
74.7
67.8
36.9
225
500
68.3
59
32.2
75.3
74.7
41.1
250
500
75.3
65.6
35.7
75.3
75.3
45.1
WASS-42-450
175
500
68.9
63.5
24.5
88.9
82
33.9
200
500
78.8
72.6
28
100.5
93.6
36.1
225
500
88.6
75.6
35.5
100.5
97.6
45.8
250
500
95.5
80.7
40.8
100.5
100.5
52.7
300
500
100.5
96.8
45
100.5
100.5
58.1
All capacities may be extrapolated for different concrete strengths 'C' by multiplying the 15N capacities by √(C/15), but limited by maximum stated values for each lifter/loadcase
Values in italics require reinforcement which may be difficult to fit within wall thickness