The Straight Rebar Anchor features a socket anchored with a reinforcing bar, ideal for casting into wall-type components parallel to the wall, offering long anchorage.
Features
Long Anchorage
High capacity due to increased anchorage in concrete.
Corrosion-Resistant Finish
Hot-dip galvanised finish provides superior corrosion resistance for both interior and exterior applications.
High capacity
Optimised for high load transfer, increasing overall connection strength and performance.
Geometry
Click to interact
Expand
1 of 3
SKU
Rd [mm]
Diameter
L [mm]
Length
Lth [mm]
Screw in depth
Ds [mm]
Socket rebar dim
RAS-12-200
12
200
25
8
RAS-16-270
16
270
27
12
RAS-20-350
20
350
35
14
RAS-24-400
24
400
43
16
RAS-30-500
30
500
56
20
RAS-36-650
36
650
69
25
RAS-42-850
42
850
80
28
RAS-52-900
52
900
100
32
Load Data
Click to interact
Expand
1 of 3
SKU
Installation Parameters
Max. Load Capacity (C15)
Max. Load Capacity (C25)
Hmin [mm]
Min. element thickness
Cmin [mm]
Min. edge distance
Fᵥ [kN]
Axial load
Fₛ [kN]
Angled load 10° to 45°
Fq [kN]
Shear load 45° to 90°
Fᵥ [kN]
Axial load
Fₛ [kN]
Angled load 10° to 45°
Fq [kN]
Shear load 45° to 90°
RAS-12-200
60
140
9
5
2.5
11
7
2.6
RAS-16-270
80
180
14
12
7.4
19
15.5
9.6
RAS-20-350
100
250
28
20
9
34
25.8
11.5
RAS-24-400
100
300
40
25
9
45
32.2
11.6
RAS-30-500
140
350
57
40
20
65
51.6
25.8
RAS-36-650
140
400
80
55.1
18.8
100
71.1
24.2
RAS-42-850
160
500
110
80
22.4
130
103.3
29
RAS-52-900
200
600
160
125
38
180
161.4
49
These tables show a typical situation and you should check if your situation is within these parameters. When your situation falls out of these parameters, please contact CFS for bespoke advice and calculations. The capacities are the same for both electroplated and stainless steel anchors.
Where two or more sockets are in use, they should be spaced at a minimum of 2xCmin apart. Minimum reinforcement of two layers of 131mm2/m mesh.
The angled and shear loads require additional reinforcement shown below.